Skip to main content

Grundfos Water Pump

Grundfos DID – Dosing Instrumentation Digital Water Quality Measurement & Control

The Grundfos DID (Dosing Instrumentation Digital) systems represent the perfect combination of s::can’s state-of-the-art digital sensor technology and Grundfos’ expertise in PID controlling of dosing and disinfection processes. Capable of measuring and controlling up to 3 water quality parameters simultaneously, DID systems are designed to match perfectly with Grundfos dosing pumps, gas dosing systems, and systems for the generation and dosing of chlorine dioxide and hypochlorite. Monitoring typical water quality parameters and precise control of disinfectant addition or pH adjustment is essential for many water treatment processes.

As an authorized Grundfos Water Pump Dealer in Dubai, we supply the complete DID range with genuine warranty and technical support across the UAE.

Grundfos DID Dosing Instrumentation Digital-Water Treatment

CU 382 Control Unit Specifications

ParameterSpecification
ElectronicsHigh-speed 32 bit Cortex M4 processor
Display128 x 64 graphical display, 70 x 40 mm viewing area, transreflective, white background
Memory512 MB, industrial grade SLC
Data LoggerInternal memory, downloadable via USB stick
InterfacesRS-485 Modbus
Ambient Temperature-20 to +45°C
Permissible Relative Humidity5 to 90%, non-condensing
Voltage100-240 V, 50/60 Hz
Enclosure ClassIP65

CU 382 Outputs & Inputs

TypeQuantityDescription
Analog Outputs3 x 4-20 mAFreely assignable controller outputs
Analog Input1 x 4-20 mAExternal signal input
Potential-Free Outputs2Digital control outputs
Alarm Relay1Fault notification
Potential-Free Inputs2External signal inputs

Sensor Specifications

Disinfectant Sensors

ParameterFree ChlorineTotal ChlorineClO₂H₂O₂PAA
Operating Temperature+5 to +45°C+5 to +45°C+5 to +50°C+5 to +45°C+5 to +45°C
Max. Operating Pressure3 bar3 bar1.0 bar1.0 bar1.0 bar
Min. Flow Rate30 l/h30 l/h30 l/h30 l/h30-100 l/h
Response Time (t90)2 min2 min1 min8 min5 min at 10°C / 1.5 min at 50°C
Measuring Range0-2 ppm / 0-20 ppm0-2 ppm / 0-20 ppm0-2 ppm / 0-20 ppm0-200 ppm / 0-2000 ppm0-200 ppm / 0-2000 ppm

Water Quality Sensors

ParameterpHORPConductivity
Operating Temperature0 to +70°C0 to +70°C0 to +70°C
Max. Operating Pressure0-10 bar0-10 bar0-20 bar
Min. Flow Speed0.01-3 m/s0.01-3 m/s0.01-3 m/s
Response Time (t90)30 s30 s60 s
Measuring RangepH 2-12-2000 to +2000 mV0-500000 µS/cm

System Configuration Options

Bypass Flow Cell Systems

Intended for monitoring and control of:

ParameterApplication
Free ChlorineDrinking water disinfection
Total ChlorineSwimming pool treatment
ClO₂Chlorine dioxide monitoring
pHAcid/base dosing control
ORPOxidation-reduction potential
ConductivityWater quality monitoring
TemperatureProcess temperature tracking

Bypass System Features:

  • Water flow maintained at appropriate level by flow restrictor
  • Flow switch detects lack of water and triggers alarm
  • Shut-off ball valve included
  • Sampling cock for manual testing
  • Compatible with Grundfos standard hoses

Tank Immersion Systems

Available with up to 2 sensors for:

Sensor OptionsApplication
pH SensorDirect tank pH measurement
ORP SensorDirect tank ORP measurement
Conductivity SensorDirect tank conductivity
TemperatureAlways included

Tank Immersion Features:

  • Direct measurement in tank or basin
  • No bypass line required
  • No flow cell needed
  • 7.5 m cable included (extensions up to 20 m available)
  • Sensor carrier and guard included
  • Wall mount or DIN rail mounting options

CU 382 Control Unit Features

Intuitive Plain-Text Operation

User-friendly interface with clear menu navigation for easy setup and operation.

Data Logger Functionality

Internal memory stores measurement data, downloadable via USB stick for analysis and documentation.

Up to 3 Controller Outputs

Three freely assignable 4-20 mA outputs for controlling multiple dosing pumps or systems simultaneously.

Modbus Communication

  • RS-485 Modbus interface included
  • Modbus sensor interface for digital sensors
  • Integration with SCADA and BMS systems

Data Interchange

USB stick compatibility for easy data transfer and configuration backup.

Wide-Range Power Supply

100-240 V, 50/60 Hz universal power supply for global installation flexibility.


Sensor Features

Digital Modbus Interface

All sensors communicate with CU 382 control unit via Modbus protocol for reliable digital signal transmission.

Onboard Calibration Storage

Calibration data stored directly in each sensor, maintaining accuracy after sensor replacement.

Temperature Compensation

Automatic temperature compensation included for all sensors, ensuring accurate measurements across operating temperature range.

Pre-Calibrated Sensors

pH, ORP, and conductivity sensors arrive pre-calibrated, reducing commissioning time.

Long Service Intervals

Designed for extended operation between maintenance, minimizing operational costs.

Diaphragm-Covered Amperometric Principle

Disinfectant sensors use advanced amperometric measurement technology for accurate chlorine and oxidant detection.

Low pH Dependency

Free-chlorine sensors feature low pH dependency for accurate measurement across varying pH conditions.


Installation Configurations

DID with Bypass Flow Cell

ComponentDescription
1DID with bypass flow cell
2SMART Digital dosing pump
3Dosing tank
4Sample water extraction
5Sample water outlet to drain
6Bypass flow cell (1 or 3 sensors) with sample water extraction
7Flowmeter
8Signal cable to CU 382 control unit
9CU 382 control unit
10Control cable to pump
11Dosing line
12Injection unit

DID for Tank Immersion

ComponentDescription
2SMART Digital dosing pump
3Dosing tank
9CU 382 control unit
10Control cable to pump
11Dosing line
13Tank
14Sensor with carrier and guard
15Signal cable: sensor to CU 382 control unit

Measured Parameters Overview

ParameterSensor TypePrimary Applications
Free ChlorineAmperometricDrinking water, pool disinfection
Total ChlorineAmperometricCombined chlorine monitoring
Chlorine Dioxide (ClO₂)AmperometricClO₂ disinfection systems
Hydrogen Peroxide (H₂O₂)AmperometricAdvanced oxidation processes
Peracetic Acid (PAA)AmperometricFood & beverage disinfection
pHElectrochemicalAcid/base dosing control
ORPElectrochemicalOxidation potential monitoring
ConductivityElectrochemicalTDS and salinity monitoring
TemperatureIntegratedProcess temperature monitoring

Applications

Drinking Water Treatment

  • Chlorine disinfection control
  • pH adjustment
  • Chlorine dioxide dosing
  • Water quality monitoring

Swimming Pool & Spa

  • Free chlorine control
  • pH regulation
  • ORP monitoring
  • Conductivity tracking

Industrial Water Treatment

  • Process water conditioning
  • Cooling tower treatment
  • Boiler water monitoring
  • Wastewater pH control

Food & Beverage

  • CIP (Clean-in-Place) systems
  • Peracetic acid dosing
  • Sanitization processes
  • Rinse water quality

Pharmaceutical & Healthcare

  • Ultrapure water systems
  • Disinfection control
  • Water quality documentation
  • Regulatory compliance

System Selection Guide

ApplicationRecommended ConfigurationSensors
Pool chlorinationBypass flow cellFree chlorine + pH
Drinking waterBypass flow cellFree chlorine + pH + temperature
Industrial coolingTank immersionConductivity + pH
ClO₂ disinfectionBypass flow cellClO₂ + ORP
Wastewater pH controlTank immersionpH + ORP
Food processingBypass flow cellPAA + conductivity

Compatible Grundfos Dosing Equipment

DID systems integrate seamlessly with:

Equipment TypeExamples
Digital Dosing PumpsDDA, DDC, DDE SMART Digital series
Gas Dosing SystemsChlorine gas systems
Generation SystemsChlorine dioxide generators
Hypochlorite SystemsOn-site generation systems

Why Choose Grundfos DID?

State-of-the-Art Digital Sensors

s::can sensor technology delivers accurate, reliable measurement with digital Modbus communication.

Powerful PID Control

Grundfos expertise in dosing control ensures precise chemical addition and optimal process performance.

Complete System Integration

Designed for seamless operation with Grundfos dosing pumps and chemical generation systems.

Flexible Installation

Choose bypass flow cell for inline measurement or tank immersion for direct tank monitoring.

Industrial Protection

IP65-rated control unit operates reliably in demanding water treatment environments.

Data Documentation

Built-in data logger with USB download capability supports quality documentation and regulatory compliance.

Grundfos Accessories & Parts

Maintain optimal DID system performance with original components including replacement sensors (pH, ORP, chlorine, conductivity), calibration solutions, flow cells, sensor cables, extension cables, sensor guards, carriers, and membrane caps. We stock parts for all DID system configurations.


Select Grundfos Pumps

Browse our complete inventory of Grundfos DID dosing instrumentation systems. As Grundfos Pump Suppliers in Dubai, we provide competitive pricing, technical consultation, system design support, and prompt delivery across Dubai, Sharjah, Abu Dhabi, Ajman, and all UAE locations.

Contact us for:

  • System configuration based on your water quality parameters
  • Bypass flow cell vs tank immersion recommendations
  • Sensor selection guidance
  • Integration with existing dosing systems
  • Competitive quotations
  • Delivery schedules

Measurement and Control of Up to 3 Water Quality Parameters

The Grundfos DID system combines advanced digital sensor technology with proven PID control expertise to deliver precise water quality measurement and chemical dosing control. With sensors for free chlorine, total chlorine, ClO₂, H₂O₂, PAA, pH, ORP, and conductivity—plus the powerful CU 382 control unit featuring Modbus communication, data logging, and IP65 protection—DID provides the complete measurement and control solution for drinking water, pools, industrial processes, and beyond.