Skip to main content

Grundfos Water Pump

Grundfos CIM/CIU Communication Interfaces for Complete Pump Control

The Grundfos CIM (Communication Interface Module) and CIU (Communication Interface Unit) range provides complete control for pumps and pump systems through open, interoperable network protocols. These innovative communication interfaces enable seamless data exchange via BACnet, Modbus, PROFINET, LONWorks, EtherNet/IP, and 3G/4G cellular networks—connecting Grundfos pumps and controllers to PLC, BMS, and SCADA systems for intelligent building services, industrial automation, and water utility applications.

As an authorized Grundfos Water Pump Dealer in Dubai, we supply the complete Grundfos CIM/CIU communication interface range with genuine warranty and technical support across the UAE.

Grundfos CIM CIU Communication Interface

Available Communication Interfaces

InterfaceProtocolProduct Number
CIM 040GENI TTL98415941
CIM 050GENIbus96824631
CIM 060GlowPan (Grundfos GO Remote)98778356
CIM 100LONWorks (for pumps)96824797
CIM 110LONWorks (for boosters/twin pumps)96824798
CIM 150PROFIBUS DP96824793
CIM 200Modbus RTU96824796
CIM 260-EU3G/4G Cellular99439302
CIM 290-MALPWAN GIC (Grundfos Connect)92865300
CIM 300BACnet MS/TP96893770
CIM 500Ethernet (PROFINET/Modbus TCP/BACnet IP/EtherNet/IP)98301408
CIM 550Ethernet (Grundfos Connect)92546689

CIU Units

UnitProduct NumberDescription
CIU 90099448387Empty CIU unit for all CIM modules
CIU 90199448389CIU with built-in I/O board (IO 270)
CIU 90297644690CIU for wastewater AUTOADAPT pumps (1-4 pumps)
CIU 90398106399CIU for MGEFlex and SQFlex pumps

E-Box Units (for Small DDA Dosing Pumps)

UnitProtocolProduct Number
E-Box 150PROFIBUS DP97513994
E-Box 200Modbus RTU98563350
E-Box 500Ethernet (PROFINET/Modbus TCP/EtherNet/IP)99171932

General CIU 900/901/902 Specifications

ParameterSpecification
Supply Voltage24-240 VAC/VDC, -10%/+15%
Frequency0-60 Hz
Power ConsumptionMax. 11 W
Cable SizeIEC: 0.2-4 mm², UL: 24-12 AWG
Enclosure ClassIP54 (IEC 60529)
Cable Entry6 × M16, Ø4-Ø10
Operating Temperature-20°C to +45°C (-4°F to +113°F)
Storage Temperature-20°C to +60°C (-4°F to +140°F)
Dimensions (H × W × D)182 × 108 × 82 mm

CIU 901 I/O Board Specifications

ParameterSpecification
Configurable Inputs2 × (digital or analog 0/4-20 mA, 0-10 V)
Relay Output1 × (230 V, 2 A)
Analog Signal Output1 × (0-10 V)
Temperature Input1 × Pt100/Pt1000 (2-wire)
Digital Inputs2 ×

Protocol Specifications

GENIbus Communication:

ParameterSpecification
ProtocolGENIbus
TransceiverRS-485
Cable TypeScreened, double twisted-pair
Max Cable Length1200 m / 4000 ft

CIM 500 Industrial Ethernet:

ParameterSpecification
ProtocolsPROFINET IO (position 0), Modbus TCP (position 1), BACnet IP (position 2), EtherNet/IP (position 3)
Transmission Speed10/100 Mbit/s
Ports2 × RJ45
Conformance ClassB (PROFINET)
IP SettingsBuilt-in webserver

CIM 300 BACnet MS/TP:

ParameterSpecification
ProtocolBACnet MS/TP (Master)
TransceiverRS-485
Transmission Speeds9.6, 19.2, 38.4, 76.8 kbit/s
Master Address0-127

CIM 200 Modbus RTU:

ParameterSpecification
ProtocolModbus RTU
TransceiverRS-485
Transmission Speeds1.2, 2.4, 4.8, 9.6, 19.2, 38.4 kbit/s
Parity SettingsEven, Odd, or No parity
Stop Bits1 or 2
Slave Address1-247 (via rotary switches)

CIM 150 PROFIBUS DP:

ParameterSpecification
ProtocolPROFIBUS DP
TransceiverRS-485
Implementation ClassDP-V0
Transmission Speeds9600 bit/s to 12 Mbit/s
Slave Address1-126 (via rotary switches)

CIM 100/110 LONWorks:

ParameterSpecification
ProtocolLONtalk
TransceiverFTT-10
Transmission Speed78 kbit/s

CIM 260 3G/4G Cellular:

ParameterSpecification
ProtocolSMS, Data connection (Modbus TCP)
AntennaAvailable as option (PN 99518079)
BatteryAvailable as option (PN 99499908)
SIM CardUser/installer supplied

CIM/CIU Interface Products by Protocol

ProtocolCIM ModuleCIU 900CIU 901CIU 902CIU 903E-Box
LONWorksCIM 100/110CIU 100/110––––
PROFIBUS DPCIM 150CIU 150–CIU 152–E-Box 150
Modbus RTUCIM 200CIU 200CIU 201CIU 202–E-Box 200
BACnet MS/TPCIM 300CIU 300––––
Cellular 3G/4GCIM 260 EUCIU 260 EUCIU 261 EUCIU 262 EU––
Cellular LTE-MCIM 290-MACIU 290-MACIU 291-MACIU 292-MACIU 293-MA–
Industrial EthernetCIM 500CIU 500CIU 501CIU 502–E-Box 500
Grundfos ConnectCIM 550CIU 550CIU 551CIU 552CIU 553–

Compatible Grundfos Products

Single Pumps (CIM Internal Mount):

  • E-pumps based on MGE motor model H/I/J/K
  • E-pumps based on MGE motor 11-22 kW
  • MAGNA3 circulator pumps
  • CRE/CRNE/CRIE, MTRE, CME, TPE2/TPE3, NBE/NKE

Boosters (CIM Internal Mount):

  • Hydro/Control MPC (CU 352)
  • DDD control (CU 354)
  • Hydro Multi-E and Hydro Multi-B
  • MAGNA3-D twin circulator pumps
  • TPED twin pump model H/I/J/K

Water Utility Controllers:

  • Dedicated Controls (CU 362)
  • Level Control LC 2X1 wastewater
  • Level Control LC 2X2 submersible

Products Requiring CIU 900:

  • TPED 11-22 kW
  • CUE drive for various standard pumps
  • MP 204 motor protector
  • DDA model XL and DDA ‘C’

Data Points Available

Control Functions:

  • Operating Mode (Start/Stop/Service)
  • Setpoint adjustment
  • Control Mode selection
  • Relay Control
  • Tank filling control

Status Information:

  • Operating Mode status
  • Control Mode status
  • Feedback signals
  • Alarm/warning information
  • Bearing service information

Measured Data:

  • Power/Energy consumption
  • Pressure (Head)
  • Flow rate
  • Relative performance
  • Speed and frequency
  • Digital input/output status
  • Motor current/voltage
  • Remote flow/pressure/temperature
  • Inlet/outlet pressures
  • Level measurements
  • Operation time (run time)
  • Number of starts
  • Volume (with sensor)
  • Ambient/motor/bearing temperatures

Sub-pump Data (Multi-pump Systems):

  • Status/alarm information per pump
  • Operation time per pump
  • Speed per pump
  • Line current/power consumption
  • Motor temperature
  • Number of starts
  • Force to stop/auto control

SMS Features (CIM 260 Cellular)

FeatureCapability
Read Product StatusPressure, power, temperature (product dependent)
Request AlarmsActive alarms/warnings
Request I/O StatusSignal status information
Network StatusSignal level, battery, cellular status
Self-Triggered MessagesAlarm/warning events, heartbeat
ControlOperating mode, control mode, setpoint, reset alarms
ConfigurationPIN code access, SMS/cellular settings

Accessories

AccessoryProduct NumberDescription
CIM 060 Antenna Kit98778357For no line-of-sight applications
CIM 260 Antenna Kit995180791.5 m cable for EU 3G/4G
CIM 260 Battery99499908Power failure alarm backup
CIM 500 RJ45 Field Plug Kit984717522× RJ45 plugs for flexible cable
DDA GENIbus Cable (3 m)98589048Connection to CIU unit
Antenna 3G/4G LTE (CIM 290)998387753 m cable with magnetic base
Antenna Extension Cable 10 m92589374SMA connector (male + female)
Antenna Extension Cable 20 m92589395SMA connector (male + female)
Robustel R3000-L3H (3G Router)99043055For CIM 550 in Europe
Robustel R3000-L4L (4G Router)99043057For CIM 550 in Europe
3G/4G Rod Antenna (Robustel)990430615 m cable
External Power Supply 12V99043052For Robustel Router

Key Benefits

Improved Reliability Pumps and controllers achieve better reliability with reduced downtime through monitoring and control functionality on PLC, BMS/SCADA systems.

Reduced Operational Costs Lower operational costs by adjusting setpoints to match precise system needs via remote control.

Remote Monitoring & Control Reduce manual settings, monitoring time, and travel to sites through remote access via PLC, BMS/SCADA systems.

Predictive Maintenance Enable predictive maintenance and fast reaction time on process changes and exceptions.

Modular Design One solution for all products with modular design prepared for future needs, offering complete process monitoring and control.

Easy Installation Simple configuration saves commissioning time with Grundfos-supplied support files and functional profile manuals.

Flexible Power Supply Wide range 24-240 VAC/VDC power supply in CIU units accommodates diverse installation requirements.

Cloud Connectivity Allow SCADA systems or Grundfos iSOLUTIONS Cloud to create reports through remote monitoring and analysis.

Applications

Building Services:

  • HVAC system integration
  • Building management system connectivity
  • Energy monitoring and optimization
  • Circulator pump control

Industrial Automation:

  • Process control integration
  • PLC connectivity
  • SCADA system communication
  • Factory automation

Water Utility:

  • Pumping station monitoring
  • Wastewater treatment control
  • Level control integration
  • Remote site management

Dosing Applications:

  • Chemical dosing pump control
  • Flow monitoring
  • Batch dosing management
  • Alarm notification

Genuine Grundfos Accessories & Parts

Complete your CIM/CIU installation with genuine Grundfos accessories including antenna kits, GENIbus cables, RJ45 field plugs, routers, power supplies, and extension cables. We stock components for complete communication interface solutions.


Select Grundfos Pumps

Browse our complete inventory of Grundfos CIM/CIU communication interfaces and compatible pump systems. As Grundfos Pump Suppliers in Dubai, we provide competitive pricing, technical consultation, and prompt delivery across Dubai, Sharjah, Abu Dhabi, Ajman, and all UAE locations.

Contact us for:

  • CIM/CIU interface selection
  • Protocol compatibility guidance
  • BMS integration support
  • Antenna and accessory requirements
  • Competitive quotations
  • Delivery schedules

Complete Control Through Intelligent Communication

The Grundfos CIM/CIU communication interface range delivers the connectivity, flexibility, and intelligence that modern pump systems demand. With support for BACnet, Modbus, PROFINET, LONWorks, EtherNet/IP, and cellular networks, these interfaces enable seamless integration with building management systems, industrial PLCs, and SCADA platforms—providing complete control, monitoring, and optimization for pumps and pump systems across all applications.